Gas
Chromatographs
GC-4000
Series
GC
GC-4400
Portable Photo-Ionization Gas Chromatograph
GC-4400
Portable Photo-Ionization Gas Chromatograph
GC-4085
GC-4008B
Gas Chromatograph Specialized for Coal Mines
GC
GC
l Low-cost high-efficiency
l Uniquely designed column oven,
exceptionally low background noise
l Interchangeable, separate units provide for
easy customization
l Optional remote activation unit
l The instrument is connected to a data
processing workstation that greatly improves efficiency
l 8-ramp programmable temperature control
system
5 Detectors to choose
n Thermal Conductivity Detector (TCD) : Used for macro analysis of gases and liquids.
n Flame Ionization Detector (FID): Used for analysis of hydrocarbon group and of organic in other fields.
n Flame Photometric Detector (FPD): Used for trace level analysis of sulfide and phosphide.
n
Nitrogen-Phosphorus Detector
(NPD): Used for trace level analysis of nitride and phosphide.
n
Electron Capture Detector (ECD) : Measure compounds that are capable of capturing the
electrons.
A5000
Chromatography Data Workstation:
TD-01 Thermal Desorption Device
Coupled with GC, TD-01 Thermal Desorption can be used to detect total volatile organic compound (TVOC) for indoor or outdoor air samples.
Features
n Heating system controlled by a microprocessor. Uniquely designed heating oven. Quickly rise/drop temperature. Safe operation and good repeatability.
n Simple touch buttons on the panel, making operation easy to understand. From beginning of desorption program, to raise to temperature and inject the samples, the whole process can be completed automatically.
Unique "trigger" structured design for sampling tube,
making assembling and disassembling the sampling tubes quick and convenient,
suitable for analyzing large quantities of samples.
Characteritics:
Detector
|
Sensitivity |
Noise |
TCD |
S≤5000mv.mg/ml (benzene) |
≤0.02mv |
FID |
M≤1x10 |
≤1x10 |
ECD |
M≤2x10 |
|
FPD |
Ms≤5x10 Mp≤1x10 |
≤2x10 |
NPD |
Mn:1x10 Mp:1x10 |
|
GC
Model
|
Usage |
Major Configuration
|
|
Macro Analysis
of Gases and Liquids |
TCD |
|
General |
FID +
8-ramp programmable heating |
|
General |
2FIDs +
8-ramp programmable heating, 2 air routes |
|
General |
FID,
TCD, 8-ramp programmable heating, 2 air routes |
|
General |
2 FIDs, TCD, 8-ramp programmable heating, 3 air routes |
|
Fully
Automatic Analysis for Natural gases |
2 FIDs, TCD, special column, capillary column, one
time auto-sampler, 8-ramp
programmable heating, 3 air routes,3 sets of 6-way valves |
4006B |
Full
Analysis for Crude oil and natural gases analysis |
FID,
TCD, 3 special columns, capillary column, automatic back flushing system,
8-ramp programmable heating |
|
Full
Analysis for Crude oil and natural gases analysis |
FID, TCD,
3 special columns, capillary column, 8-ramp programmable heating,3 air
routes, 6-way valve |
4006D |
Analyzes
dry gases and oil refinery gas, etc. |
TCD, 2
packed columns, carriage gas switch system, 6-way valve |
4006E |
Analyzes
benzene and toluene in gasoline |
TCD, 1
preparative column and 1 major column, automatic back flushing system, inlet
high temperature 6 way valves |
|
Analyzes
categories of ether and alcohol in gasoline |
FID, 1 preparative
column and 1 major column, inlet 6-way valve, precut and back flushing
devices |
|
Analyzes
transformer oil |
FID, TCD, conversion oven, 2 Specialized columns,8-ramp
programmable heating,2 air routes |
|
Coal
mining GC |
2 FIDs, TCD, conversion oven, 3 special columns, 8-ramp
programmable heating,3 air routes, 3 sets of 6-way valves |
4008B |
Coal
mining GC 2 FIDs, |
TCD, conversion
oven, 4 special columns, 8-ramp programmable heating,4 air routes, 4 sets of
6-way valves |
|
Environmental
Monitoring, Hygiene and Epidemic Prevention and food Inspection |
FID,
ECD, 8-ramp programmable heating, 2 air routes |
|
Environmental
Monitoring, Hygiene and Epidemic Prevention and food Inspection |
FID,
FPD, 8-ramp programmable heating, 2 air routes |
|
Environmental
Monitoring, Hygiene and Epidemic Prevention and food Inspection |
FID, ECD,
FID, 8-ramp programmable heating, 3 air routes |
|
Analysis
of Organic chlorine and other Electronegative Material |
ECD,
8-ramp programmable heating |
|
Analysis
of Organic phosphor and other Material |
NPD,
8-ramp programmable heating |
|
General |
FID,NPD,
8-ramp programmable heating, 2 air routes |
|
Environmental
Monitoring, Hygiene and Epidemic
Prevention and food Inspection |
TCD,
NPD, 8-ramp programmable heating, 2 air routes |
|
Environmental
Monitoring, Hygiene and Epidemic Prevention and food Inspection |
ECD,
FPD, NPD, 8-ramp programmable heating, 3 air routes |
|
General |
FID,
ECD, NPD, 8-ramp programmable heating, 3 air routes |
|
Electronegative
organics, organic phosphor analysis |
ECD,NPD,
8-ramp programmable heating,2 air routes |
|
General |
TCD,
FID, ECD, 8-ramp programmable heating,3 air routes |
|
Organic
sulfur and other organics analysis |
FID,
8-ramp programmable heating |
|
General |
2 FIDs, FPD, 8-ramp programmable heating, 3 air routes |
|
Macro
analysis of gases, liquids and electronegative substances |
TCD,
ECD, 8-ramp programmable heating, 2 air routes |
|
General |
TCD, 2 FIDs, ECD, 8-ramp programmable heating, 3 air routes |
|
Organic
sulfur and electronegative substances analysis |
ECD,
FPD, 8-ramp programmable heating, 2 air routes |
|
Macro
analysis of Gases, and liquids |
2 TCDs, 8-ramp programmable heating, 2 air routes |
|
General |
FID,
FPD, NPD, 8-ramp programmable heating, 2 air routes |
|
Organic
phosphor and organic sulfur analysis |
FPD,
NPD, 8-ramp programmable heating,2 air routes |
|
Indoor air
Measurement |
FID,
8-ramp programmable heating, thermal desorption
system, capillary device |
|
Indoor
air Measurement |
2 FIDs, 8-ramp programmable heating, Thermal desorption system, capillary device |
|
Indoor
air Measurement |
TCD, FID,
8-ramp programmable heating, thermal desorption
system, capillary device |
|
General |
2 FIDs, ECD, 8-ramp programmable heating,3 air routes |
|
Macro
analysis of gases, liquids and organic sulfur |
TCD,
FPD, 8-ramp programmable heating, 2 air routes |
|
Macro
Analysis of Gases |
2 FIDs, conversion oven, 3 sets of 6-way valves,8-ramp
programmable heating, 3 air routes |
|
Macro
and Micro Analysis of Gases |
FID, TCD,
conversion oven, 2 sets 6-valves, 8-ramp programmable heating, 3 air routes |
GC-4400 Portable
Photo-Ionization Gas Chromatograph
Technical Specifications
n Utilize photon to realize ionization of samples. No radiation source.
n High sensitivity. Low limit of detection. Broad linear range.
n Light weight, manoeuvrable and flexible, especially suitable for use in analysis at scene and emergency for environment pollution accidents.
n No need of H2, combustion-assistant gases and high purity gas. Only mixed air gas is needed.
n No destrution of samples. The results are safe and reliable.
n No need of chemical pre-processing, concentration, enrichment, thermo desorption. The user can directly inject samples to analyze.
n Chromatograph workstation, composed of data acquisition card, a notebook computer and software. It carries out of data sampling, analysis, calculation, display and storing.
Compounds for Analysis:
1ppb:
Epoxy-ethane, ethene-chloride, ethane-chloride, benzene, toluene, xylene, ethane, paraffin hydrocarbon (up to octyl-alkane), isoamyl diene, ethane, propylene, butylenes, category of light weight chlorobenzene, H2S, category of light weight mercaptan, organic sulfur (up to dimenthyl disulfide), acetone, methyl-ethyl-ketone, arsine, hydrogen phosphide, acetaldehyde, category of aldehyde (up to hexyl-aldehyde) etc.
50ppb:
Category of ethylene lipid, category of fluoro-chloro-methane (freon), isocyanic-acid-methyl-lipid, category of ethyl-chloride, cyclo-hexyl-ketone, acryclic-acid-ethyl-lipid, category of light weight alcohol and etc.
Applications
It can be used in coal mine analysis labs, to analyze coal mine gas samples, to forecast fire, to monitor degree of possibility of gas explosion, and to analyze all components of fire hazard gases.
Technical Features
1.
Flexible and advanced design.
It is equipped with a TCD, duel FIDs, conversion
oven, 4 sets of 6-way valves, 4 specialized columns, 8-ramp
programmable heating devices.
2. Minimum detection limit for spontaneous combustion firing: CO, C2H2≤0.5ppm, C2H4≤0.1ppm, H2≤5ppm.
3. Be able to detect SF6 by equipped with ECD, be able to detect H2S, SO2 and other gases by equipped with FPD.
4. Utilize the specially designed explosion triangle software, to monitor degree of possibility of gas explosion based on analysis results.
GC-4085
As one of the advanced products specialized for coal mine safety monitoring, with more than 10 years experience in the field, it has been recognized as an industrial standard by our customers, it becomes the one of most reliable equipments used in thousands of China's coal mines.
Applications
1. Forecast and predict, in early stage, natural burning in coal. Continuously monitor the patterns and trend of benchmark gas
components and concentrations, so to prevent coal natural burning and gas
explosion.
2.
Monitor the development in closed firing area, providing scientific data for
re-opening of work areas in the accidents aftermath.
3. In fire extinguish and fire protection by inert gases, trace and