UV/Vis
spectrophotometer
T60
New Century
The T60 New Century is an affordable Dual Beam UV Visible Spectrophotometer with a fixed slit of 2nm. The T60 has a small footprint and has pre-programmed PCMA cards for quantitative analysis, scanning, kinetics and DNA. The T60 can be interfaced to a PC via UV Spec Software. The system is supplied with an 8 cell motorized cell changer as standard.
Specifications:
•Dual beam UV-Vis spectrophotometer
•Wavelength Range: 190-1100nm, Spectral bandwidth: 2nm
•Wavelength accuracy: ±1nm, Wavelength repeatability: ≤0.2nm
•Photometric accuracy: ±0.3%T, Photometric repeatability: ≤0.15%T
•Stray light: ≤0.05%T at 220nm(NaI) and at 340nm(NaNO2)
T60
The T60 Aurora is a Dual Beam Visible range Spectrophotometer with a fixed slit of 2nm. The T60 has a small footprint and has pre-programmed PCMA cards for quantitative analysis, scanning, kinetics and DNA. The T60 can be interfaced to a PC via UV Spec Software. The system is supplied with an 8 cell motorized cell changer as standard.
Specifications:
•Dual beam Vis spectrophotometer
•
•Wavelength accuracy: ±2nm,
Wavelength repeatability: ≤0.4nm
•Photometric accuracy: ±0.3%T,
Photometric repeatability: ≤0.15%T
•Stray light: ≤0.1%T at 340nm(NaNO2)
T70 UV
Spectrophotometer
The T70 UV Spectrophotometer is a dual beam instrument with
a fixed 2nm bandwidth. The T70 has a large 'fold away' LCD display unit which
allows full complete display of Spectra. The system has a large easy to use
positive touch key pad and the instrument can be used a complete standalone
unit.
T70+ UV Spectrophotometer
The T70 UV Spectrophotometer is a
dual beam instrument with a variable bandwidth of 0.5, 1.0, 2.0 and 5.0nm.
The T70 has a large 'fold away' LCD display unit which allows full complete
display of Spectra. The system has a large easy to use positive touch key pad
and the instrument can be used a complete standalone unit.
Specifications:
Dual beam UV-Vis spectrophotometer
Wavelength accuracy: ±0.5nm, Wavelength repeatability: ≤0.2nm
Photometric accuracy: ±0.3%T, Photometric repeatability: ≤0.15%T
T80/
T80+ Double Beam UV Spectrophotometer
The optical system for T80/T80+ adopts
a split-beam measurement optical system, detector for two highly sensitive
silicon photodiodes; instrument operations are controlled through an internal
single-chip microcomputer, matched with a 320*240 LCD display screen and a
soft-touch keypad and parallel printing interface. TU-1800/1800S UV-VIS
spectrophotometer performs photometric measurements, spectrum measurements, and
quantitative measurements.
Specifications:
Double beam UV-Vis spectrophotometer |
|
Wavelength range |
190nm ~ 1100nm |
Spectral
bandwidth |
0.5nm, 1.0 nm, 2.0 nm and 5.0 (for T-80+) |
2.0 nm (for T-80) |
|
Wavelength
accuracy |
±0.5nm, Wavelength
repeatability: ≤0.2nm |
Photometric accuracy |
±0.3%T, Photometric
repeatability: ≤0.15%T |
T90 AND T90+ DOUBLE BEAM UV VISIBLE SPECTROPHOTOMETER
Specifications:
1)
Optical System: |
Double Beam |
-
Wavelength range: |
190 nm – 900 nm |
-
Variable Spectral bandwidth: |
0.1, 0.2, 0.5nm, 1.0nm, 2.0nm,
and 5.0 nm. (Fixed 2nm Band pass on T90) |
-
Stray Light: |
0.02%T |
-
Wavelength accuracy: |
±0.3 nm (automatic
correction) |
-
Wavelength Reproducibility: |
0.1 nm |
2)
Photometric System: |
The double-beam ratio
recording system. |
- Optical
System: |
The monochromator
of Czerny-Turner configuration with high-resolution diffraction holographic
grating. |
- Photometric
Method: |
Transmittance,
absorbance, reflectance, energy, concentration. |
-
Photometric Range: |
-4.0 ~ 4.0 Abs |
-
Photometric Accuracy: |
0.3%T 0.300%T |
-
Photometric Reproducibility: |
0.001Abs(0~0.5 Abs)
0.001Abs(0.5~1.0 Abs) 0.15%T (0~100%T), |
-
Baseline flatness: |
±0.001Abs |
-
Resolution: |
0.1nm |
-
Baseline stability: |
0.0004Abs/h (@ 500nm, after
preheating) |
-
|
-9.999 to 9.999 ABS |
-
Continuously variable spectral bandiwth from: |
0.1, 0.2, 0.5, 1.0, 2.0
and 5.0 nm. |
-Scanning Speed: |
1000
nm/min |
-Interface Card: |
PC Compatible |
-Detector: |
High sensitivity R928
multiplier detector. |
-Photometric Display: |
Unlimited |
-Photometric Noise: |
<±0.0003 Abs (500nm,
0Abs, 2nm Bandwidth) |
-Slew rate of wavelength: |
2400nm/min |
3) DNA/RNA Measurement: |
Available in UV Win
Software |
- Results Printout. |
Directly form PC system. |
4)
Mainframe: |
Compact and standalone
spectrophotometer mainframe |
- Light Source: |
Socket Deuterium Lamp and
Socket Tungsten Halogen Lamp. |
- Sample Chamber: |
With accessories such as two-cell
sample holder and optional integrating sphere. |
- Size: |
|
- Weight: |
|