PH
Electrode
Model |
Application |
PH Combined Electrode with Glass Body |
|
65-IP |
General lab and field use |
65-IIP |
|
65-IA |
For viscous solutions and lab use |
65-IIA |
For viscous solutions |
PH Combined Electrode with Plastic Body |
|
84-IP |
General lab and field use |
84-IIP |
for use with pH meter P-IA and
PX-IA |
87-IP |
for use with pH meter PH-I |
87-IIP |
for use with pH meter PH-II or lab
|
87-IIIP |
for use with pH meter PH-III or
lab |
88-IP |
General lab and field use |
88-IIP |
|
88-IA |
|
89-I |
|
99-I |
with double layer. aquarium
and fish farming use |
99-IA |
|
PS-02 |
skin, fruit, sheet, piece goods
and etc. |
PE-200 |
General lab and field use with
temperature sensor |
ORP Combined Electrode with Plastic Body |
|
|
For lab application, especially
useful for solution that is corrosive to PC plastic and circumstances where
higher temperature is consecutiely measured.
Normally used with reductive media. |
|
|
Conductivity Electrode with Glass Body |
|
DJS-1 |
Used for determination of
electricity conductivity or conductivity titration of solution |
DJS-2 |
|
DO Electrode with Plastic Body |
|
ZDO-1 |
Dissolved Oxygen electrode |
PH
Combined Electrode with Glass Body
Model |
65-IP |
65-IIP |
Measuring Range |
0
– 14 pH |
|
|
0
– |
|
Zero point value |
7
+/- 1 pH |
|
Junction |
Ceramic |
|
Reference Cell |
Ag/Agcl, KCL solution refillable |
Ag/Agcl, KCL gel |
Size |
dia.12
x length |
|
Plug |
BNC
+ |
Note: Difference
between the two models is the reference cell electrolyte. 65-IP is with solution
form and can be refilled. 65-IIP is in gel form which last life time, not need
to refill.
Model |
65-IA |
65-IIA |
Measuring Range |
0 - 14 pH |
|
|
0 - |
|
Zero point value |
7 +/- 1 pH |
|
Junction |
Ceramic |
|
Reference Cell |
Ag/Agcl,
KCL solution refillable |
|
Size |
dia.9 x length |
|
Plug |
BNC + |
Note: Difference
between the two models is the shape of the tip. 65-IA is sharper and 65-IIA is
a little round.
PH Combined Electrode with Plastic Body
Model |
84-IP |
84-IIP |
Measuring
Range |
0
- 14 pH |
|
|
0
- |
|
Zero
point value |
7
+/- 1 pH |
|
Junction |
Ceramic |
|
Reference
Cell |
Ag/Agcl, KCL gel |
|
Size |
dia.10
x length |
|
Plug |
BNC
+ |
BNC |
Note: 84-IP
can be generally used in lab. 84-IIP is the accessory electrode for pH meter
model P-IA and PX-IA. It has a special direct BNC plug to be connected to pH
meter.
Model |
87-IP |
87-IIP |
87-IIIP |
Measuring
Range |
0
- 14 pH |
||
|
0
- |
||
Zero
point value |
7
+/- 1 pH |
||
Junction |
Ceramic |
||
Reference
Cell |
Ag/Agcl, KCL gel |
||
Size |
dia.12
x length |
dia.12
x length |
dia.12
x length |
Plug |
Special
direct plug |
BNC |
BNC
+ |
Note: These
three models are accessories for Pocket pH meter PH series.
General
lab and field use
Model |
88-IP |
88-IIP |
88-IA |
Measuring Range |
0
- 14 pH |
||
|
0
- |
||
Zero point value |
7
+/- 1 pH |
||
Junction |
Ceramic |
||
Reference Cell |
Ag/Agcl, KCL gel |
Ag/Agcl, KCL gel (tine vesicle) |
|
Size |
dia.12
x length |
||
Plug |
BNC
+ |
Note:
General lab and field use pH electrodes.
Model |
89-I |
Measuring Range |
0 - 14 pH |
|
0 - |
Zero point value |
7 +/- 1 pH |
Junction |
Ceramic |
Reference Cell |
Ag/Agcl,
KCL gel |
Size |
dia.12 x length |
Plug |
BNC |
Note: With direct BNC plug for general lab and field use
with
double layer. aquarium and fish farming use
Model |
99-I |
99-IA |
Measuring
Range |
0
- 14 pH |
|
|
0
- |
|
Zero
point value |
7
+/- 1 pH |
|
Junction |
Fiber |
|
Reference
Cell |
Ag/Agcl, KCL gel |
Ag/Agcl, KCL gel (tine vesicle) |
Size |
dia.12
x length |
|
Plug |
BNC
+ |
Note: Double layer electrodes. Suitable for continuous measurement. 99-IA is with sharp tip.
skin,
fruit, sheet, piece goods and etc.
Model |
PS-02 |
Measuring
Range |
0
- 14 pH |
|
0
- |
Zero
point value |
7
+/- 1 pH |
Junction |
Ceramic |
Reference
Cell |
Ag/Agcl, KCL gel |
Size |
dia.12
x length |
Plug |
BNC + |
Note: Can be used for measuring skin, sheet, wood and etc.
General
lab and field use with temperature sensor
Model |
PE-200 |
Measuring
Range |
0
- 14 pH |
|
0
- |
Zero
point value |
7
+/- 1 pH |
Junction |
Ceramic |
Reference
Cell |
Ag/Agcl, KCL gel |
Size |
dia.12
x length |
Plug |
BNC
+ |
Note: With
temperature sensor, can be used with pH meters with ATC (Automatic Temperature
Compensation) function.
ORP Combined Electrode
with Plastic Body
For lab application, especially useful
for solution that is corrosive to PC plastic and circumstances where higher
temperature is consecutively measured. Normally used with reductive media.
Model |
|
|
Measuring
Range |
+/-
1500 mV |
|
Junction |
Ceramic |
|
Reference
Cell |
Ag/Agcl, KCL gel |
|
Sensitive Component |
dia.1
x |
dia.6
x |
Size |
dia.12
x length |
|
Plug |
BNC
+ |
Note: Difference between the two models is the shape of the sensitive component. A is needle and B is ring.
Conductivity
Electrode with Glass Body
Used for determination of electricity
conductivity or conductivity titration of solution
Model |
DJS-1 |
DJS-2 |
Sensitive
Component |
5
x |
5
x |
Size |
dia.12
x length |
dia.12
x length |
Cell
Constant |
1 |
|
Plug |
BNC
+ |
DO Electrode with Plastic Body
Dissolved Oxygen electrode
Model |
ZDO-1 |
Residue
current |
=<
0.005 uA |
Response
time |
30
seconds for 90% |
Measuring
range |
0
- 20 ppm |
Stability |
+/-
0.2 ppm when ambient temperature varies +/- |
Note: Dissolved Oxygen electrode. Self-stirring oxygen sensor simultaneous stir and measure
Laboratory Electrode—Plastic pH
Combination Electrode
Model 201-C Plastic pH Combination
Electrode
Range: 0~14pH
Temperature range: 0~
Junction: ceramic
Type reference: Ag/ AgCl
Dimensions: Φ12 x
Connector: BNC
Characteristic: PC housing, anti-collision. The protecting cap can
be taken down, it’s convenient for cleaning. It needn’t renew gelatinous KCL.
Application range: For laboratory application especially suitable
for outdoors using and online. It is unsuitable for the following
circumstances:
●
When the measure solutions is alkaline, (pH>12)
●
When the solution causes erosion to the body.
●
The consecutively measured temperature is higher (>
Model 200-C Plastic
pH Combination Electrode
Range: 0~14pH
Temperature range: 0~
Junction: ceramic
Type reference: Ag/ AgCl
Dimensions: Φ12 x
Connector: BNC
Characteristic and application range: same as the 201-C basically,
the difference is that it can be refilled KCL solution. So its accuracy is
higher while the consecutively measured.
201-A Plastic pH Combination Electrode
Range: 0~14pH
Temperature range: 0~
Junction: ceramic
Type reference: Ag/ AgCl
Dimensions: Φ12 x
Connector: BNC without cable
Characteristic and application range: same as the 201-C the
difference is that it is adopted a connector without cable, suitable for use of
pH meter for hand type, it can also use with a extent
cable.
206-C Plastic Mini pH Combination Electrode
Range: 0~14pH
Temperature range: 0~
Junction: ceramic
Type reference: Ag/ AgCl
Dimensions: Φ12 x
Connector: BNC
Characteristic and application range: same as the 201-C basically,
but the outside diameter is shorter, except for routine measurement, it’s
better to be suitable for use of test tube and a small quantity of sample.
Model 2501-C Glass pH
Combination Electrode
Range: 0~14pH
Temperature range: 0~
Junction: ceramic
Type reference: Ag/ AgCl
Dimensions: Φ12 x
Connector: BNC
Characteristic: For accurate pH measurement, it’s routine
combination electrode which is high quality. Especially suitable for solution
that is corrosive to plastic body of electrode and circumstances where higher
temperature is consecutively measured. Unsuitable for sticky
solution which is caused a jam for ceramic junction, and strong base solution.
Model 2511-C Glass pH
Combination Electrode
Range: 0~14pH
Temperature range: 0~
Junction: ceramic
Type reference: Ag/ AgCl
Dimensions: Φ12
x
Connector: BNC
Characteristic: glass
body, gel KCL, non-refillable.
Application range:
same as 2501-C, it’s convenient for using, but the operating temperature is
lower.
Model
2503-C Glass pH Combination Electrode
Range: 0~14pH
Temperature range: 0~
Junction: ground
glass sleeve
Type reference:
capillary Ag/ AgCl
Dimensions: Φ12
x
Connector: BNC
Characteristic: glass
body, KCL reference solution can be refilled. Junction is ground glass sleeve.
Application range: Be
suitable for use of solution which is weaker ionic strength, high viscosity and
feculent and colloidal solution.
Laboratory
Electrode-pH Electrode for Special Purpose
Model 2503S-C Glass
pH Combination Electrode
Range: 0~10pH
Temperature range: 20~
Junction: ground glass sleeve
Type reference: capillary Ag/ AgCl
Dimensions: Φ12 x
Connector: BNC
Characteristic and application range: special sensitive glass film
is used, suitable for measuring in high temperature and strong acid.
Model 2503D-C Glass
pH Combination Electrode
Range: 2~12pH
Temperature range: 0~
Junction: ground
glass sleeve
Type reference:
capillary Ag/ AgCl
Dimensions: Φ12
x
Connector: BNC
Characteristic and
application range: low impedance sensitive glass membrane(<=15MΩ)is
used, suitable for low temperature and pure water.
Model 2015P-C Flat pH Combination Electrode
Range: 0~14pH
Temperature range: 5~
Junction: cricoid teflon
Type reference: Ag/ AgCl
Dimensions: Φ15
x
Connector: BNC
Characteristic and
Application range: PVC body, gelatinous KCL, flat sensitive membrane, suitable
for flat surface object (such as skin, paper etc.) and minim solution.
Laboratory Electrode-ORP Electrode, Conductivity Electrode
Model
Range: +/-1500mV
Junction: ceramic
Type reference: Ag/AgCl
Dimensions: Φ12
x
Connector: BNC
Sensitive component: Φ6
x
Characteristic: PC
body, gel KCL, non-refillable.
Application range:
for lab and field applications, measuring oxidation reduction potential for
solution. Generally, it is suitable for use of oxidation system.
Model
Range:
+/-1500mV
Junction: ceramic
Type reference: Ag/AgCl
Dimensions: Φ12
x
Connector: BNC
Sensitive component: Φ6
x
Characteristic: Glass
body, KCL, reference solution can be refilled.
Application range:
Typical for lab applications, especially suitable for solution that is
corrosive to PC plastic body and circumstances where higher temperature and
consecutively measuring. Generally, it is suitable for use of oxidation system.